4. Move the positioning pins on the 2 LCT fixing plates
to the front holes (1 screw each).
LCT Fixing Plate
5. Install the 2 LCT fixing plates on the Main body
with 2 screws (M4x8) each as shown in the figure.
6. Remove the single screw holding the left side cover
to the Main body.
7. Remove the single screw from the connector cover
and remove it from the Main body.
Positioning pin
TP screws M4x8
Connector cover
E-5
8. Install the Main body earth plate/rear onto the Main
body with TP screw M4x20 (1 screw) and TP screw
M3x6 (1 screw) included in the accessory parts.
9. Install the earth plate with TP screw M3x6 (1 screw)
included in the accessory parts.
Main body earth plate/rear
TP screws M4x6
Earth Plate
10. Attach the vibration cushion on the top of the left
side of the LCT.
Vibration cushion
11. Install 2 LCT Connector jacks to the connector
plugs on the Main body.
Caution:
Keep the connector portion of the LCT near to the
Main body as close as possible, in order to avoid
any damage against the connector wires owing to
their short length.
TP screws M4x20
TP screws M3x6