EXTERNAL SECTION
[1] Replacing Ozone Filters
Caution: Be sure the power cord has
been unplugged from the wall
outlet.
Caution: When replacing ozone filters, insert
them in the openings in the main body
as far as they will go.
a.
Procedure
(1) Loosen the two screws to remove the cooling fan
cover.
(2) Replace two ozone filters 1 (upper/2) and one
ozone filter 2 (lower/1).
Ozone filter 2
(3) Reinstall the above parts following the removal
steps in reverse.
Ozone filter 1
Screws
(loosen 2)
Cooling cover
[2] Removing and Reinstalling the
External Cover
Caution: Be sure the power cord has
a. Procedure
(1) Remove the two screws to detach the option
cover.
(2) Remove the nine screws to detach the rear cover.
Option cover 1
(3) Remove the six screws to detach the left side
cover.
Screws (6)
3 - A - 1
EXTERNAL SECTION
been unplugged from the wall
outlet.
Rear cover 1
Screws (9)
Screws (2)
Left side cover