3. Connect the other connector of the printer relay
wiring / 2 already connected to the printer relay
board / 2, to the video interface port of the IP-
602.
Video interface port
Printer relay wiring / 2
4. Make sure the voltage-setting switch next to the
connection for the power cord is set for the cor-
rect power voltage.
115
100-120V
230
220-240V
230
5. Connect the IP-602 to the power supply socket
inside the main unit frame following the proce-
dure below.
(1) Connect the connector of the power cord to
the power socket (below) of the IP-602, and
connect the other connector of the power cord
to the power supply socket (above) inside the
main unit frame.
(2) Use the cable tie (supplied with the VI-602) to
firmly fix the connected power cord to the main
unit power cord.
Power supply socket
Power cord
Cable tie
6. When using the network cable and the parallel
cable connect them to the IP-602 following the
procedure below.
(1) Connect the connector of the network cable to
the RJ45 connector of the IP-602.
(2) Connect the connector of the parallel cable to
the parallel connector of the IP-602.
Network cable
Parallel cable
E-2
Main unit
power cord
Parallel
connector
RJ45
connector