FIXING UNIT
[12] Removing and Reinstalling the
Fixing Separation Claws (Upper)
a.
Procedure
(1) Open the fixing paper exit unit.
(2) Remove the six springs connected to the fixing
separation claws.
(3) Remove the six fixing separation claws.
Spring
(4) Reinstall the above parts following the removal
steps in reverse.
[13] Removing and Reinstalling the
Fixing
separation
claws
(upper)
3 - O - 12
3 - O - 8
Actuator for Fixing Exit PS (PS2)
a.
Procedure
(1) Open the fixing paper exit unit.
(2) Disconnect the two connectors (CN464, 465)
(3) Remove one screw to detach the fixing separation
claw (lower) (on the drive side).
(4) Remove the two screws to detach the actuator/
sensor assembly.
Connectors
(CN465)
Connectors (CN464)
(5) Remove the spring from the actuator/sensor
assembly to detach the actuator for fixing exit PS
(PS2).
(6) Reinstall the above parts following the removal
steps in reverse.
Screws
Actuator/
sensor
assembly
Fixing paper exit
actuator