READ SECTION
(5) The exposure unit mounting plate is installed on
each optics wire. The position of mounting plate
differs depending on whether it is installed on the
front or rear wire. Use the wire on which the
mounting plate is installed nearer to the metal
bead at the end, at the rear.
(6) Place the metal bead at the midpoint of each
optics wire in the mounting hole in the drive
pulley. Starting at this point, wind the optics wire
five turns to the outside and four times to the
inside on the drive pulley.
Caution 1: Ensure that there is a metal bead
at the end of the outer wire, and a
wire terminal at the end of the inner
wire.
Caution 2: Pull out the outer wire from above
the drive pulley in the paper exit
direction, and the inner wire from
under the drive pulley in the paper
feed direction.
(7) After winding the outer wire, secure it to the wire
stopper via the outside of pulley 1 and V-mirror
pulley.