Table C-2
Event Code
10
15
17
18
20
21
22
23
26
Polycom, Inc.
CDR Event Types (Continued)
Event Name
Description
DEFINED
Information about a defined participant, that is, a participant
PARTICIPANT
who was added to the conference before the conference
started.
For more information about the fields, see Table C-14, "Event
Fields for Events 10, 101, 105 - DEFINED PARTICIPANT,
USER ADD PARTICIPANT, USER UPDATE PARTICIPANT,"
on page C-20.
Note: There is one event for each participant defined before
the conference started.
H323 CALL
Information about the IP address of the participant.
SETUP
For more information about the fields, see Table C-17, "Event
fields for Event 15 - H323 CALL SETUP," on page C-24.
H323
An H.323 participant connected to the conference.
PARTICIPANT
For more information about the fields, see Table C-18, "Event
CONNECTED
Fields for Events 17, 23 - H323 PARTICIPANT CONNECTED,
SIP PARTICIPANT CONNECTED," on page C-25.
NEW
A new undefined participant joined the conference.
UNDEFINED
For more information about the fields, see Table C-19, "Event
PARTICIPANT
Fields for Event 18 - NEW UNDEFINED PARTICIPANT," on
page C-26.
BILLING CODE
A billing code was entered by a participant using DTMF codes.
For more information about the fields, see Table C-21, "Event
Fields for Event 20 - BILLING CODE," on page C-29.
SET
A user assigned a new name to a participant, or an end point
PARTICIPANT
sent its name.
DISPLAY NAME
For more information about the fields, see Table C-22, "Event
Fields for Event 21 - SET PARTICIPANT DISPLAY NAME," on
page C-30.
DTMF CODE
An error occurred when a participant entered a DTMF code.
FAILURE
For more information about the fields, see Table C-23, "Event
Fields for Event 22 - DTMF CODE FAILURE," on page C-30.
SIP
A SIP participant connected to the conference.
PARTICIPANT
For more information about the fields, see Table C-18, "Event
CONNECTED
Fields for Events 17, 23 - H323 PARTICIPANT CONNECTED,
SIP PARTICIPANT CONNECTED," on page C-25.
RECORDING
A recording event, such as recording started or recording
LINK
resumed, occurred.
For more information about the fields, see Table C-24, "Event
fields for Event 26 - RECORDING LINK," on page C-30.
Appendix C-CDR Fields - Unformatted File