Issue 13.0
With Version 8000 or higher software, PCPro and WebPro have been enhanced allowing
T1/ISDN layer 1 status, System Alarms and SRAM information to be viewed. The SRAM
displays Day/Night Mode information, Trunk information (Trunk to Trunk Transfer Set/Not
Set, Trunk disabled), Read List, Department Group information (DND, Transfer settings)
and Extension information (Forwarding settings, Alarm settings, DND, BGM and more).
This feature requires Version 8000 Enhanced (0037) license and Maintenance (0043)
license.
Refer to the UNIVERGE SV8100 PC Programming Manual, Appendix L, Maintenance Features for more
details.
With Version 9000 or higher software, WebPro has been enhanced to allow for remote
upgrade and is only available in the Manufacture (MF) and Installer (IN) level logins.
With Version 9000 or higher software, WebPro has been enhanced to allow for Backup of
the system data and also the restoring of a Backup.
Backup data is in the GZIP (.gz) format.
Backup is not able to be modified.
When the Backup is restored, the system resets after the upload is completed.
Only available in Manufacture (MF), Installer (IN), and System Administrator 1 (SA1) level
logins.

Outbound IP Connection

Description
Outbound IP Connection for PC Programming allows the system to make
outgoing call over IP, to a pre-programmed IP Address, upon receipt of an incoming CO call matching a
pre-programmed CLI. When the target number of DID incoming call matches with the service code of
'Outbound IP Connection' the SV8100 compares the received CLI with the registered CLI (Program
90-69-03). When the received caller ID and registered caller ID match, the SV8100 sends a TCP
establishment request to a waiting PCPro application. When the caller ID does not match, the call will
either step to the locations in Program 22-11-05 and Program 22-11-06 if configured or, send a busy tone
to the caller. Alternatively, via dialing service code from a Multiline Terminal, an outgoing IP connection
can be made to a waiting PCPro terminal with a pre-programmed IP Address. This allows for a
pre-authorized connection for programming purposes without using CO Lines and potentially reducing
the cost of calls for maintenance. The outgoing IP call connects by sending a TCP establishment request
to a waiting PC Programming terminal. A fixed, encrypted, user ID and password are used to verify the
connection.
If an unsuccessful connection attempt is made, this can be output as an alarm.