NEC Univerge SV8100 Features And Specifications Manual page 1478

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 13.0
Program
Program Name
Number
11-07-01
Department Group Pilot
Numbers – Dial
15-03-01
Single Line Telephone Basic
Data Setup – SLT Signaling Type
15-03-03
Single Line Telephone Basic
Data Setup – Terminal Type
15-07-01
Programmable Function Keys
16-01-01
Department Group Basic Data
Setup – Department Name
16-01-02
Department Group Basic Data
Setup – Department Calling
Cycle
16-01-03
Department Group Basic Data
Setup – Department Routing
When Busy (Auto Step Call)
16-01-04
Department Group Basic Data
Setup – Hunting Mode
2 - 1444
Description/Comments
Assign a Department Group pilot
number for the CD-PVAA (eight
digits max). The extensions are
assigned to the group in Program
16-02-01.
For each SLT extension, this
option must be set to 0.
Enter 1 for this option to allow a
single line port to receive DTMF
tones after the initial call setup.
Enter 0 to have the port ignore
DTMF tones after the initial call
setup. For Voice Mail, always
enter 1 (e.g., receive DTMF
tones).
Program one Call Appearance
(CAP) key on each SMB
Conference Bridge extension.
Assign a name to the Extension
(Department) Groups.
Set the call routing for Department
Calling. Routing can be either
circular (cycle to all phones in a
group) or priority (cycle to highest
priority extension first).
Set how the system routes an
Intercom call to a busy
Department Group member.
Intercom callers to the extension
can either hear busy or route to
the first available department
number. This occurs only for direct
calls to the extension, not the
department number assigned in
Program 11-07.
Set the action taken when a call
reaches the last extension in the
Department Group. Hunting is
stopped or cycling repeats.
UNIVERGE SV8100
Assigned Data
1
Up to eight digits
(default not assigned)
0 = DP
1 = DTMF
(default = 1)
0 = Normal
1 = Special
(default = 0)
(
08 + XXXX = CAP
key where XXXX is the
CAP orbit number
0001-9999)
(Appearance Function
Code) (Service Code
752 by default)
Maximum 12
characters
(default = No Setting)
0 = Normal Routing
(Priority)
1 = Easy – UCD
Routing (Circular)
(default = 0)
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle member)
(default = 0)
0 = Last extension is
called and hunting is
stopped
1 = Circular
(default = 0)
SMB8000 Conference Bridge
Level
2
3

Advertisement

Table of Contents
loading

Table of Contents