Issue 13.0
In the card configuration window, if you click a card type in the main menu, the menu
closes. You must mouse over the card type to open the submenu to list all cards of that
type.
To access the modem over K-CCIS, route the modem access service code to the target
switch. Do not call a station that is call forwarded to the service code. When accessing the
modem over K-CCIS, enter the service code to be dialed in PC Pro.
PC Pro follows the PC dialing properties. If dialing a service code, you must turn off the dial 9 for
outside line and area code inclusion or PC Pro will dial these digits as well.
Some program items require second initialization of the KTS before they take effect. These
Programs are: 10-12-01, 10-12-02, 10-12-03, 10-12-04, 10-13-01, 10-13-02, 10-13-03,
10-14, 10-15, 10-16-01, 10-16-02, 10-16-03, 10-16-04, 20-01-03, 47-01-01, 80-01,
80-02-01, 80-02-02, 80-02-03, 80-02-04, 80-03, 80-04, 84-03-01, 84-03-02, 84-03-06,
84-03-07, 84-03-08, 84-05-01, 84-05-02, 84-06-01, 84-06-02, 84-06-03, 84-06-04,
84-06-05, 84-06-06, 84-06-07, 84-06-08, 84-06-09, 84-06-10, 84-06-11, 84-09 and 84-10.
These caution statements do not apply to Version 2.0 or higher software.
PCPro converts an Electra Elite IPK II PCPro database file into a SV8100 PCPro database
file. PCPro Software Version 3.00 or higher is required.
The system data to be converted is limited to the system data listed below.
2 - 1252
Failure to properly install and program ports higher than 64 (as
described below) can corrupt the SV8100 database.
If the PZ-ME50-US is not physically installed on the CD-CP00-US, do
not attempt to change the PCPro database configuration to indicate that
the PZ-ME50-US is installed on the CD-CP00-US, program ports 64 and
higher and then upload the PCPro configuration to the SV8100 system.
This process can corrupt the SV8100 database. Refer to the next bullet for
the proper installation/programming procedure.
To properly install and configure the PZ-ME50-US; first install the
PZ-ME50-US on the CD-CP00-US. Next, you must reload the system
software. With the PZ-ME50-US installed, a portion of the main software
is loaded onto the PZ-ME50-US.
Before attempting to program the ports above 64 using PCPro, a new
download must be performed after the PZ-ME50-US is installed.
PRG No.
10-23
IP System Interconnection Setup
11-01
System Numbering
11-02
Extension Numbering
Name
UNIVERGE SV8100
PC Programming