NEC Univerge SV8100 Features And Specifications Manual page 1668

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 13.0
Required Component(s)
None
Related Features
Call Forwarding, Off-Premise
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Method A – Tandem Trunking from Conference:
Program
Program Name
Number
11-12-57
Service Code Setup (for Service
Access) – Tandem Trunking
14-01-04
Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
14-01-05
Basic Trunk Data Setup –
Receive Gain Level for
Conference and Transfer Calls
2 - 1634
Description/Comments
#
If the default service code (
Tandem Trunking is not
acceptable, change the code as
required.
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
Tandem Trunking (Unsupervised Conference)
UNIVERGE SV8100
Assigned Data
8) for
MLT, SLT
#
(default =
8)
1~63(-15.5dB~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
1~63(-15.5dB~
+15.5dB in 0.5dB
intervals)
[default = 16 (-8dB)]