UNIVERGE SV8100
Conditions
Version 6.00 or higher SV8100 system software is required for Outbound IP Connection
for PC Programming.
R6 PC Programming or higher is required for Outbound IP Connection for PC
Programming.
Outbound IP Connection for programming is not available when an existing WebPro/PCPro
or station programming session is active.
SV8100 changes the port number of TCP at each connection. The range used is
61050~61099.
Outbound IP Connection Service code can be dialed across CCIS.
Outbound IP Connection to a secondary side of Net-Link is not supported.
Default Setting
None
System Availability
Terminals
All Terminals
Required Software
None
Required Component(s)
CPU
PC Programming
R6000 Enhancement (0035) license (for Outbound IP Connection)
Maintenance (0043) License (for Outbound IP Connection)
PC Programming
Issue 13.0
2 - 1255