NEC Univerge SV8100 Features And Specifications Manual page 899

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
15-05-45
IP Telephone Terminal Basic
Data Setup – NAT Plug and Play
15-05-47
IP Telephone Terminal Basic
Data Setup – Registration Expire
Timer for NAT
15-05-48
IP Telephone Terminal Basic
Data Setup – Subscribe Expire
Timer for NAT
84-20-01
SIP Extension Basic Information
Setup – Registrar/Proxy Port
IP Single Line Telephone (SIP) – NAT Mode
Description/Comments
This program is valid when
Program 10-46-14 is On (NAT
feature activated).
Select sending RTP port number
to remote Router, use from
negotiation result (0) or received
RTP packet (1).
SV8100 uses this program to
decide a destination port of RTP
transmitting packets from IPLB to
a remote IP terminal. If "0:OFF" is
selected, the destination port of
RTP transmitting packets will be a
SIP/SDP negotiation result.(same
behavior as before). If you chose
"1:ON", the destination port of RTP
transmitting packet will be the
same port of a source port of a
receiving RTP packet on IPLB
(PZ( )IPLB required).
On a per station basis, this setting
defines the SIP registration expiry
timer.
If this value is set to 0, for a NAPT
terminal, the value in Program
84-23-01 is applied.
Version 9000 or higher
required.
With Version 9.5 or higher
software, when the uMobility
client connects via NAT, this
must be set to 60 seconds.
On a per station basis, this setting
defines the SIP Subscribe expiry
timer.
If this value is set to 0, for a NAPT
terminal, the value in Program
84-23-02 is applied.
Version 9000 or higher
required.
Define SIP station Proxy Port.
Assigned Data
1
0 = Disable
1 = Enable
(default = 0)
0 = Disable
60~65535 (sec)
(default = 180)
0 = Disable
60~65535 (sec)
(default = 180)
1~65535
(default = 5070)
Issue 13.0
Level
2
3
2 - 865