Issue 13.0
Program
Program Name
Number
84-26-03
IPL Basic Setup – RTCP Port
Number (RTP Port Number + 1)
90-10-01
System Alarm Setup – Alarm
Type
SIP Trunk E.164 Support
Program
Program Name
Number
10-02-01
Location Setup – Country Code
10-02-02
Location Setup – International
Access Codes
44-01-02
System Options for ARS/F-Route
– Dial Tone Simulation
44-01-03
System Options for ARS/F-Route
– Tone Type
2 - 888
Description/Comments
Define the TCP port number for
RTCP to use for each DSP.
Define if Alarms are Minor, Major,
or Not Set.
Description/Comments
Enter the country code.
Enter the international access
code.
When first dialed, digit matches
the data set in this Program,
system sends simulated DT to
calling party after receiving first
digit. Numbering plan for the dial
needs to be configured as F-Route
in Program 11-01.
Set simulated DT to type which
can change the tone used in
Program 44-01-02 and Program
44-02-04.
IP Trunk – (SIP) Session Initiation Protocol
UNIVERGE SV8100
Assigned Data
1
0~65534
Defaults:
VoIP GW1 = 10021
VoIP GW2 = 10053
VoIP GW3 = 10085
VoIP GW4 = 10117
VoIP GW5 = 10149
VoIP GW6 = 10181
VoIP GW7 = 10213
VoIP GW8 = 10245
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
(default not assigned)
Assigned Data
1
Dial (up to four digits):
#
0~9, ,
(default = 1)
Dial (up to four digits):
#
0~9, ,
(default not assigned)
1 Digit (0~9)
#
(,
cannot be used)
(default not assigned)
0 = Internal Dial Tone
1 = External Dial Tone
(default = 0)
Level
2
3
Level
2
3