NEC Univerge SV8100 Features And Specifications Manual page 1577

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
After seven days, the license expires. To renew the license, a connection to the original
Primary site must be re-established. (Once the connection to the Primary is recovered, if
fail-over occurs again, the license is once again enabled for seven days to the new Primary
System). Version 4000 or lower software required.
After twenty-eight days, the license expires. To renew the license, a connection to the
original Primary site must be re-established. (Once the connection to the Primary is
recovered, if fail-over occurs again, the license is once again enabled for twenty-eight days
to the new Primary System). Version 4000 (4.01 or higher) software required.
If the original Primary site is in the NetLink network as a temporary secondary, the license
information is available.
If a user wants to enter another additional feature license, it needs to be entered on the
original Primary System.
When fail-over occurs, the Primary System is changed to another communication server.
The IP applications do not know the new primary IP Address, so the following features are
disabled after fail-over:
SMDR
ACD-MIS
SIP Terminal
Soft Phone
IP K-CCIS
The following Programs are not updated by the Primary System during fail-over :
Program 10-01, Program 10-02, Program 10-12, Program 10-13, Program 10-14, Program
10-15, Program 10-16, Program 10-45, Program 51-01, Program 90-01 or Program 90-09.
Data in SRAM area is not transferred to the Secondary Systems during fail-over, therefore
when fail-over occurs DND and Caller ID History may be lost.
When a Secondary System with an ETIA or RTB assigned is added to a NetLink network,
the Primary Systems database does not replicate the data in Programs 10-55 or 90-61.
When using Netlink and UCB, the trunks and extensions on the remote sites are not
supported for UCB with Version 2500 (2.50 or lower).
When External MOH is assigned, the CN8 or CN9 on the front of the CD-CP00-US can only
be utilized at the Primary Site. All Secondary sites must provide the External MOH input via
an ACI Input [PGD(2)-U10 ADP]. Version 2500 (2.51 or lower).
With Version 3000 or higher, both the Primary Site and Secondary Sites can have their
own local MOH source connected to the CN8 or CN9 on the front of the CD-CP00-US.
With Version 3000 or higher, the T-1 CCTA and PVA-CCIS blade is supported in the
primary system and/or secondary systems.
When using Netlink and UCB, the trunks and extensions on the remote sites are supported
for UCB with Version 2500 (2.51 or higher).
SV8100 NetLink
Issue 13.0
2 - 1543

Advertisement

Table of Contents
loading

Table of Contents