NEC Univerge SV8100 Features And Specifications Manual page 863

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
15-07-01
Programmable Function Keys
20-02-12
System Options for Multiline
Telephones – Forced Intercom
Ring (ICM Call Type)
20-06-01
Class of Service for Extensions
20-08-11
Class of Service Options
(Outgoing Call Service) – Protect
for the Call Mode Switching from
Caller
IP Multiline Station (SIP) – ML440/G566/G266 with AP400/AP300
Description/Comments
Assign functions to multiline
terminal line keys.
NEC recommends the following
for the first three programmable
keys on a ML440:
Line Keys 1 and 2 = CAP Keys
Line Key 3 = Intercom Key
Enable/Disable Forced Intercom
Ringing. If enabled, incoming
Intercom calls normally ring. If
disabled, Intercom calls
voice-announce.
This should be set to Signal
(1) or each ML440 should be
set to Signal manually using
dial access code 723.
Assign ML440 handsets to their
own Class of Service.
Set this option for the ML440/
G566/G266 handset Class of
Service. When an extension is set
to ring mode for ICM calls,
enabling this option prevents
callers from changing the call to
voice announce mode.
This setting should be
Enabled (1) for the ML440/
G566/G266 handset Class of
Service.
Assigned Data
1
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
*00 ~ 99*
(Appearance Function
Code) (Service Code
752 by default)
(*08 + XXXX = CAP
key where XXXX is the
CAP orbit number
0001-9999)
0 = Disable (Voice)
1 = Enable (Signal)
(default = 0)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
0 = Off
1 = On
(default = 0 for
COS 1~15)
Issue 13.0
Level
2
3
2 - 829

Advertisement

Table of Contents
loading

Table of Contents