product_part_number = 602-4954-02
product_serial_number = BDL1026F8F
product_manufacturer = Oracle Corporation
fault_state = OK
clear_fault_action = (none)
power_state = On
Commands:
cd
reset
set
show
start
stop
Note – When a PDB, fan board, or HDD backplane is replaced, the chassis serial
number and part number might need to be programmed into the new component.
This must be done in a special service mode by trained service personnel.
▼ Locate the Server
You can use the Locator LEDs to pinpoint the location of a server. This procedure is
helpful when you need to identify one particular server from many other servers.
1. At the ILOM command line, type:
-> set /SYS/LOCATE value=Fast_Blink
The white Locator LEDs (one on the front panel and one on the rear panel) blink.
2. After locating the server with the blinking Locator LED, turn it off by pressing
the Locator button.
Note – Alternatively, you can turn off the Locator LED by running the ILOM
set /SYS/LOCATE value=off command.
Related Information
"Front Components" on page 1
■
Preparing for Service
65
Need help?
Do you have a question about the SPARC T3-2 and is the answer not in the manual?
Questions and answers