2. Identify the faulty fan module with a corresponding Service Required LED.
The Service Action Required LEDs are located on the fan module as shown in
"Locate a Faulty Fan Module" on page
3. Using your thumb and forefinger, grasp the handle on the fan module and lift it
out of the server.
Caution – When removing a fan module, do not rock it back and forth. Rocking fan
modules can cause damage to the fan board connectors.
Caution – When changing fan modules, note that only the fan modules can be
removed or replaced. Do not service any other components in the fan compartment
unless the system is shut down and the power cords are removed.
Related Information
"Extend the Server to the Maintenance Position" on page 72
■
"Install a Fan Module" on page 98
■
95.
Servicing Fan Modules
97
Need help?
Do you have a question about the SPARC T3-2 and is the answer not in the manual?