1. After replacing a faulty FRU, power on the server.
2. At the host prompt, use the fmadm faulty command to determine whether the
replaced FRU still shows a faulty state.
# fmadm faulty
TIME
EVENT-ID
Aug 13 11:48:33 ********-****-****-****-************
Platform
: sun4v
Product_sn
:
Fault class : fault.cpu.generic-sparc.strand
Affects
: cpu:///cpuid=**/serial=*********************
FRU
: "/SYS/MB"
(hc://:product-id=*****:product-sn=**********:server-id=***-******-*****:
chassis-id=********:**************-**********:serial=******:revision=05/
chassis=0/motherboard=0)
Description : The number of correctable errors associated with this strand has
exceeded acceptable levels.
Refer to http://sun.com/msg/SUN4V-8002-6E for more information.
Response
: The fault manager will attempt to remove the affected strand
from service.
Impact
: System performance may be affected.
Action
: Schedule a repair procedure to replace the affected resource, the
identity of which can be determined using 'fmadm faulty'.
If no fault is reported, you do not need to do anything else. Do not perform the
subsequent steps.
If a fault is reported, continue to
Chassis_id
faulted and taken out of service
faulty
:
Step
3.
MSG-ID
SEVERITY
SUN4V-8002-6E
Major
Detecting and Managing Faults
43