Servicing the Fan Board
These topics explain how to remove and install the server's fan board.
"Remove the Fan Board" on page 157
■
"Install the Fan Board" on page 159
■
"Verify Fan Board Functionality" on page 161
■
▼ Remove the Fan Board
Caution – These procedures require that you handle components that are sensitive
to static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
page
63.
This is a cold service procedure that must be performed by qualified service
personnel. The system must be completely powered down before performing this
procedure. See
page 67
for more information about this category of service procedures.
1. Prepare for servicing:
a. Attach an antistatic wrist strap.
b. Power off the server and unplug power cords from the power supplies.
See
"Removing Power From the System" on page
c. Extend the server to the maintenance position.
See
"Extend the Server to the Maintenance Position" on page
d. Remove the top cover.
See
"Remove the Server Top Cover" on page
"Cold Service, Replaceable by Authorized Service Personnel" on
"ESD Measures" on
69.
72.
76.
157