▼ Check for Faults With the fmadm faulty
Command
The following is an example of the fmadm faulty command reporting on the same
power supply fault as shown in the show faulty example. Note that the two
examples show the same UUID value.
The fmadm faulty command was invoked from within the ILOM faultmgmt shell.
Note – The characters "SPT" at the beginning of the message ID indicate that the
fault was detected by Oracle ILOM.
1. At the -> prompt, access the faultmgmt shell.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
2. At the faultmgmtsp> prompt, enter the fmadm faulty command.
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ ------------ -------
Time
------------------- ------------------------------------ ------------ -------
2010-08-11/14:54:23 ********-****-****-****-************ SPT-8000-LC
Fault class : fault.chassis.power.volt-fail
Description : A Power Supply voltage level has exceeded acceptible limits.
Response
: The service required LED on the chassis and on the affected
Power Supply may be illuminated.
Impact
: Server will be powered down when there are insufficient
operational power supplies
Action
: The administrator should review the ILOM event log for
additional information pertaining to this diagnosis.
refer to the Details section of the Knowledge Article for
additional information.
faultmgmtsp> exit