6. Run the show faulty command.
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
If the show faulty command reports a fault with a UUID go on to
show faulty does not report a fault with a UUID, you are done with the
verification process.
7. Switch to the system console and type the fmadm repaired command, using
the same FRU ID that was displayed from the output of the Oracle ILOM show
faulty command.
# fmadm repaired /SYS/MB/CMP0/MR1/BOB1/CM0/D0
Related Information
"DIMM Population Rules" on page 112
■
"Supported Memory Configurations" on page 113
■
"DIMM FRU Names" on page 114
■
"DIMM Configuration Error Messages" on page 132
■
Oracle Integrated Lights Out Manager (ILOM) 3.1 Document Collection
■
DIMM Configuration Error Messages
This topic includes the following:
"DIMM Configuration Errors—System Console" on page 133
■
"DIMM Configuration Errors—show faulty Command Output" on page 135
■
"DIMM Configuration Errors—fmadm faulty Output" on page 136
■
132
SPARC T3-2 Server Service Manual • December 2013
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
|
| timestamp
|
| Value
| /SYS/MB/CMP0/MR1/BOB1/CH0/D0
| Dec 14 22:43:59
| SUN4V-8000-DX
|
| 3aa7c854-9667-e176-efe5-e487e520
| 7a8a
| Dec 14 22:43:59
|
Step
7. If
Need help?
Do you have a question about the SPARC T3-2 and is the answer not in the manual?
Questions and answers