Fan Module Overview

The six fan modules in the server are located at the front of the chassis; you can
access them without removing the server cover. Each fan module contains a single
fan that is mounted in an integrated, hot-swappable CRU.
Caution – While the fan modules provide some cooling redundancy, if a fan module
fails, replace it as soon as possible to maintain server availability. When you remove
one of the fans in the back row, you must replace it within 30 seconds to prevent
overheating of the server.
Related Information
"Understanding Component Replacement Categories" on page 66
"Remove a Fan Module" on page 96
"Install a Fan Module" on page 98
"Verify Fan Module Functionality" on page 99