3. To obtain more information on faults, run the show faulty command.
See
Related Information
"Clear POST-Detected Faults" on page 51
■
"POST Overview" on page 45
■
FIGURE: Flowchart of ILOM Properties Used to Manage POST Operations on
■
page 47
"ILOM Properties that Affect POST Behavior" on page 46
■
"Configure How POST Runs" on page 48
■
"Run POST With Maximum Testing" on page 49
■
▼ Clear POST-Detected Faults
Use this procedure if you suspect that a fault was not automatically cleared. This
procedure describes how to identify a POST-detected fault and, if necessary,
manually clear the fault.
In most cases, when POST detects a faulty component, POST logs the fault and
automatically takes the failed component out of operation by placing the component
in the ASR blacklist (see
Commands" on page
Usually, when a faulty component is replaced, the replacement is detected when the
service processor is reset or power cycled, and the fault is automatically cleared from
the system.
1. After replacing a faulty FRU, at the Oracle ILOM prompt use the show faulty
command to identify POST detected faults.
POST detected faults are distinguished from other kinds of faults by the text:
Forced fail. No UUID number is reported. Example:
-> show faulty
Target
----------------------+------------------------+-----------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
"Check for Faults Using the show faulty Command" on page
"Managing Components With Automatic System Recovery
54).
| Property
| fru
| timestamp
| timestamp
|
| sp_detected_fault
|
| Value
| /SYS/MB/CMP0/MR0/B0B0/CH0/D0
| Dec 21 16:40:56
| Dec 21 16:40:56
|
| /SYS/MB/CMP0/MR0/B0B0/CH0/D0
| Forced fail(POST)
Detecting and Managing Faults