trigger = none
verbosity = min
Commands:
cd
set
show
->
Related Information
"POST Overview" on page 45
■
"ILOM Properties that Affect POST Behavior" on page 46
■
"Run POST With Maximum Testing" on page 49
■
"Interpret POST Fault Messages" on page 50
■
"Clear POST-Detected Faults" on page 51
■
▼ Run POST With Maximum Testing
This procedure describes how to configure the server to run the maximum level of
POST.
1. Access the ILOM -> prompt:
See
"Access the Service Processor (Oracle ILOM)" on page
2. Set the virtual keyswitch to diag so that POST will run in service mode.
-> set /SYS keyswitch_state=diag
Set 'keyswitch_state' to 'Diag'
3. Reset the system so that POST runs.
There are several ways to initiate a reset. The following example shows a reset by
issuing commands that will power cycle the host.
-> stop /SYS
Are you sure you want to stop /SYS (y/n)? y
Stopping /SYS
-> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS
24.
Detecting and Managing Faults
49