Install A Power Supply - Sun Oracle SPARC T3-2 Service Manual

Hide thumbs Also See for SPARC T3-2:
Table of Contents

Advertisement

▼ Install a Power Supply

Caution – Install an A239A power supply, labeled for upright installation, in the
server. The A239A power supply correctly exhausts air from the rear of the server. Do
not install an A239 power supply, which might cause the system to overheat and shut
down.
1. Align the power supply with the empty power supply chassis bay.
2. Slide the power supply into the bay until it is fully seated.
3. Move the release latch up to secure the power supply in place.
4. Reconnect the power cord to the power supply.
5. Verify that the AC OK LED is lit.
See
6. Verify that the following LEDs are not lit:
106
SPARC T3-2 Server Service Manual • December 2013
"Locate a Faulty Power Supply" on page
Service Action Required LED on the power supply
Front and rear Service Action Required LEDs
Rear PS Failure LED on the bezel of the server
102.