Clear Psh-Detected Faults - Sun Oracle SPARC T3-2 Service Manual

Hide thumbs Also See for SPARC T3-2:
Table of Contents

Advertisement

2. Use the message ID to obtain more information about this type of fault:
a. Obtain the message ID from console output or from the ILOM show faulty
b. Enter the message ID at the end of the Predictive Self-Healing Knowledge
Correctable strand errors exceeded acceptable levels
Type
Fault
Severity
Major
Description
The number of correctable errors associated with this strand has exceeded
acceptable levels.
Automated Response
The fault manager will attempt to remove the affected strand from service.
Impact
System performance may be affected.
Suggested Action for System Administrator
Schedule a repair procedure to replace the affected resource, the identity
of which can be determined using fmadm faulty.
Details
There is no more information available at this time.
3. Follow the suggested actions to repair the fault.
Related Information
"Clear PSH-Detected Faults" on page 42
"PSH-Detected Fault Example" on page 40

▼ Clear PSH-Detected Faults

When the Oracle Solaris PSH facility detects faults, the faults are logged and
displayed on the console. In most cases, after the fault is repaired, the corrected state
is detected by the system and the fault condition is repaired automatically. However,
this repair should be verified. In cases where the fault condition is not automatically
cleared, the fault must be cleared manually.
42
SPARC T3-2 Server Service Manual • December 2013
command.
Article web site, http://www.sun.com/msg. In the current example, enter
this in the browser address window:
http://www.sun.com/msg/SUN4V-8002-6E
The following example shows the message ID SUN4V-8002-6E and provides
information for corrective action.