AT command
AT*DGARL=<n>
Sets host (APN) to reject
[,<cid>]
transmissions for incoming packet
communications. APN settings
use <cid> parameter defined by
"+CGDCONT".
[M]
AT*DRPW
Displays the reception power sent
from FOMA terminal.
[M]
AT*DGPIR=<n> Setting this command is valid
when establishing
communication. Enables adding
186 (send caller ID) and 184 (not
send caller ID) to host number.
Also available in dial-up network
*2
settings.
[M]
+++
Switches the FOMA terminal
mode from online data mode to
online command mode.
Escape guard interval is fixed at 1
second.
*2
[M]
AT+CACM=[<p
Resets the total accumulated cost
asswd>]
recorded on the UIM.
[M]
AT+CAOC=[<m
Inquires the current accumulated
ode>]
cost.
*2
[M]
AT+CBC
Inquires the battery status.
[M]
AT+CBST=[<sp
Sets the bearer service when
eed>[,<name>[,
establishing transmission. This
<ce>]]]
setting is only valid when
AT+FCLASS=<n> command
(nP. 28) = 0.
[M]
AT+CEER
Displays disconnection reason for
preceding communication
session.
*2
[M]
Overview
Adds or deletes from Reject calls list with <n>
parameter. If <cid> parameter is abbreviated,
adds (<n>=0) or deletes (<n>=1) all of <cid>
or from list. Adds (deletes) <cid> not defined
*2
with "+CGDCONT" to (from) list with this
command.
n=0: Adds to list (Adds APN defined by <cid>
n=1: Deletes from list (Deletes APN defined
The result from this command is in the
*2
following format.
*DRPW:<m>
m: 0 to 75 (reception power)
n=0: When establishing packet transmission,
n=1: When establishing packet transmission,
n=2: When establishing packet transmission,
When 186 (send caller ID)/184 (not send
caller ID) are set by this command and in the
dial-up network settings, refer to "Send/Not
send setting on dial-up networks" on P. 13.
―
Resets the total accumulated cost recorded
*2
on the UIM, if the password matches.
<passwd>: SIM PIN2
※ Encloses this string parameter with
<mode>
0:
The result from this command is in the
following format.
+CAOC:"<ccm>"
*2
The result from this command is in the
following format.
+CBC:<bcs>,<bcl>
<bcs>
0:
1:
2:
3:
<bcl>
0 to 100 (remaining battery power)
<speed>
116: 64K data communication (default setting)
<name>
1:
*1
<ce>
0:
Refer to "Reasons for disconnection"
(nP. 32).
Parameter/Explanation
to Reject calls list)
by <cid> from Reject calls list)
connects to host (APN) directly (default
setting)
adds 184 and connects to host (APN)
adds 186 and connects to host (APN)
quotation marks (" ") when entering.
Inquires the cost of current call
The battery operates the FOMA terminal
Charging the battery
The battery is unconnected
Reducing the power
Fixed value
Fixed value
25
Execution
example
AT*DGARL=0,1o
OK
AT*DGARL?o
*DGARL:1
OK
AT*DRPWo
*DRPW:0
OK
AT*DGPIR=0o
OK
AT*DGPIR?o
*DGPIR:0
OK
(During
communication)
+++ (Does not
appear)
OK
AT+CACM="0123"
o
OK
AT+CAOCo
+CAOC:"00001E"
OK
AT+CBCo
+CBC:0,80
OK
AT+CBST=116,1,
0o
OK
AT+CEERo
+CEER:36
OK