Issue 7.0
Program
Program Name
Number
80-04-03
Call Progress Tone Detector
Setup – S/N Ratio
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON Minimum Time
2 - 1698
Description/Comments
Define the S/N ratio for the Call
Progress Tone Detector.
Define the no tone time for the Call
Progress Tone Detector.
Define the pulse count for the Call
Progress Tone Detector.
Define the on minimum time for
the Call Progress Tone Detector.
UNIVERGE SV8100
Assigned Data
1
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
0~255
(30+30-7680 ms)
The formula is 30+30N.
When set to N=1, it
means 30+30*1= 60
When set to N=255, it
means
30+30*255=7680
(0 =not detect)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255
(30+30-7680ms)
default:
Type 1
(DT) – 9 (30 ms)
Type 2
(BT) – 12 (300ms)
Type 3
(RBT) – 25 (780ms)
Type 4, Type 5 – 0
Voice Mail Integration (Analog)