6.3.4

Installing the new PSU module

Figure 31: Installing the PSU
Ê Insert the PSU module into its slot.
Ê Push the PSU module into its slot (1) as far as it will go until the locking latch
snaps in place (2).
V
CAUTION!
Ensure that the PSU module properly engages in its slot and is locked
in position in order to prevent it from sliding out of the chassis during
transportation.
Ê If applicable, fold down the handle on the PSU module (3).
6.3.5

Concluding steps

Perform the following procedures:
"Connecting the server to the power source" on page 81
Ê
Ê In non-redundant PSU configurations, swich on the server as described in
section
"Switching on the server" on page 82
"Performing a fan test after replacing a defective fan" on page 114
Ê
RX300 S7
Upgrade and Maintenance Manual
Power supply
125