Power supply
6.2.3

Removing a PSU module

Figure 29: Removing the PSU
Ê Press in on the green locking latch (1).
Ê Fold up the handle on the PSU module (2).
Ê While keeping the green locking latch pressed, pull the PSU module out of
its slot (3).