Fujitsu PRIMERGY RX300 S7 Upgrade And Maintenance Manual page 63

Hide thumbs Also See for PRIMERGY RX300 S7:
Table of Contents

Advertisement

Ê Press the Indicate CSS button (1) to highlight defective components.
Component LEDs
I
LEDs A, B and C are visible from the outside on the server rear. All other
LEDs are only visible if the server cover has been opened. In order to
access fan LEDs (O), the fan modules need to be removed
(see section
Indicator
A
Identification
CSS
B
(Customer Self
Service)
GEL
C
(Global Error
LED)
F
Controller
G
CPU
Memory
H
module
I
PS CTRL OK
K
PS CTRL Error orange on
L
Main power
RX300 S7
"Removing a fan module" on page
Status
blue on
blue
flashing
off
yellow on
yellow
flashing
off
orange on
orange
flashing
orange on
orange on
orange on
green on
green on
Upgrade and Maintenance Manual
Basic hardware procedures
179).
Description
server has been highlighted using the ID
button on the front panel for easy
identification
server has been highlighted using IRMC
(AVR) when local VGA off for easy
identification
no critical event (CSS component)
prefailure detected (CSS component)
CSS component failure
no critical event (non CSS component)
prefailure detected (non CSS
component)
non CSS component failure
Possible reasons:
– sensors report overheating
– sensor is defective
– CPU error
– software reports an error
controller faulty
CPU faulty
memory module faulty
power supply OK
powe supply error
voltage ok
63