6.
Remove the four screws (CP(W) M4x10) securing the CR motor and remove the CR
motor with roller.
Figure 4-115. CR Motor Removal
When removing the CR Motor, the following adjustment procedures
are required.
n
"CR Timing Belt Tension Adjustment"
Pay attention so as not to scar the steel belt.
Disassembly & assembly
Screw
Roller
CR motor

4.2.3.9 Removing the PF Motor ASSY

1.
Remove the L Side Cover as described in "L Side Cover Removal 124.
2.
Remove the Rear Cover as described in "Rear Cover Removal 126.
3.
Disconnect the PF Motor ASSY cable connector.
PF Motor cable connector
4.
Loosen the four (CP(W) M4x10) screws securing the PF motor bracket.