4.2.9.3 Motor Assy., PF

1.
Remove "Cover, Side, Left" (p216).
2. Disconnect "Motor Assy., PF" harness (CN14: black, 2 pin) from "C593
MAIN Board" and peel off the acetate tape to release the harnesses.
(Refer to "4.2.4.1 C593 MAIN Board" (p226).)
3. Release "Motor Assy., PF" harness and other harnesses from the two tabs
and the three grooves on "Paper Guide, Lower".
4. Peel off the pieces of acetate tape to release "Motor Assy., PF" harness
and then pull it through the hole in the frame.
5. Remove the two screws securing the "Guide, FFC" and then lower the
"Guide, FFC" along with all FFCs.
(Refer to Figure 4-209.)
C.B.S. 3x6:
1 pc.
C.B. 3x4:
1 pcs.
Align the dowel of the frame with "Guide, FFC" positioning
hole.
(Refer to Figure 4-209.)
Harness
Figure 4-207. Releasing the Harness_1
Disassembly & Assembly
(Refer to Figure 4-207.)
(Refer to Figure 4-208.)
Tabs
Paper Guide, Lower
Channels
Disassembly Procedures
Acetate Tape (x3)
Figure 4-208. Releasing the Harness_2
Guide, FFC
C.B. 3x4
Dowels and Positioning Holes
Figure 4-209. Releasing Guide, FFC
Revision C
Motor Assy., PF
FFC
C.B.S 3x6