Pf Timing Belt Tension Adjustment; P_Thick Sensor Fixing Bracket Adjustment - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF

5.2.3.2 PF timing belt tension adjustment

This adjustment is apply to all the work with PF timing belt detachment such as PF motor
removal etc., Confirm that is specified tension at the time of PF timing belt installation.
Standard: 3.5 kg+/-10%(The tension toward PF motor fixing bracket)
<Adjustment procedure>
1.
Remove the side cover L. (7 screws)
2.
Loosen 4 screws on the PF motor fixing bracket.
3.
Hook the tension gauge to the PF motor shaft.
4.
Hooks the tension gauge and keep the tension within 3.5 kg+/-10% then fix the
motor fixing bracket with four screws.
5.
Attach the cover which are removed with step 1.
PF timing belt
Figure 5-3. PF timing belt tension adjustment
Adjustment

5.2.3.3 P_THICK sensor fixing bracket adjustment

When you change the position of fixing bracket, perform the following adjustment with
self-diagnostic function.
Standard: 0.6mm: Thin paper determination /0.7mm:Thick paper determination
<Adjustment procedure>
1.
Remove the H top cover (6 screws).
2.
Select the "Test: Sensor" from the diagnostic mode and performs "Paper Thickness".
3.
Place the long hand side of filler gauge between the right edge of detection roll and
sub_platen.Adjust the fixing position which obtains "Thick paper" with 0.7 mm gauge
and "thin paper" for 0.6mm.
4.
Attach the H top cover which are removed with step 1.
Figure 5-4. P-Thick sensor adjustment
Adjustment Steps
Revision B
P_THICK sensor