3.2.6.6 Removing the MOTOR ASSY.,PF

Remove the printer mechanism. (Refer to Section 3.2.6.1.)
Step 1 :
Step
2:
Remove the two saews CS(P4) (M3 x 6) securing the MOTOR ASSY.,PF.
Remove the SHAfl,PF,TENSION securing the MOTOR ASSY.,PF, then remove the
Step 3:
MOTOR ASSY.,PF.
The following adjustments must be performed when the carn"age unit is removed or
replaced: TIMING BELT,CR Tension Adjustment (See Section 4.4.)
FRAME ASS

Figure 3-15. Removing the MOTOR ASSY.,PF

3.2.6.7 Removing the MOTOR ASSY.,CR

Step 1 :
Remove the printer mechanism. (Refer to Section 3.2.6.1)
Step 2:
Remove the saew CBS (M3 x 6) securing the GROUNDING PLATE,FFC with external
cooling fan to FRAME,CR and remove the GROUNDING PLATE,FFC.
Step 3:
Remove the EXTENSION SPRING2275 and untie the tension of TIMING BELT,CR.
Step 4:
Remove the four screws CP(M3 x 16) securing the MOTOR ASSY.,CR to the FRAME,CR
and the saew CBS (M3 x 6) securing the GROUNDING PLATE,CR,MOTOR, then
remove the MOTOR ASSY.,CR.
GROUNDING

Figure 3-16. Removing the MOTOR ASSY.,CR