EPSON Stylus Pro 10000/10000CF

5.2.3.5 Front cover sensor adjustment

<Standard>
Determines whether a finger enters into the front cover or not.
Cover open: The position whether a finger entered into the front cover or not.
Cover close: The position which a finger entered into the front cover.
<Adjustment procedure>
1.
Remove the Panel Assy, side cover L/ R and R inside cover.
2.
Select the "Test: Sensor" from the diagnostic mode and choose the "front cover
sensor".
3.
Loosen the each two fixing screws at the left and right, then move up and down each
lever and adjust the sensor position.
4.
Attach the cover which are removed with step 1.
Adjustment
Figure 5-6.

5.2.3.6 Slide idler gear / Slide motor fixing plate adjustment

<Adjustment procedure>
1.
Remove the Panel Assy and side cover R.
2.
Loosen two screws on the slide motor fixing plate, adjust the gear gutter with PG gear
on the carriage and idler gear from top direction.
3.
Fixing the screws.
4.
Attach the cover which are removed with step 1.
PG Gear
Slide Motor
Meshing returns with gear spring even if it thrust in biting condition, and
minimize the gear gutter as much as possible furthermore.
Adjustment Steps
Revision B
Idler Gear
Figure 5-7.