Pf Scale; Pf Motor Assy - Epson WorkForce 600 Service Manual

Hide thumbs Also See for WorkForce 600:
Table of Contents

Advertisement

EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW

4.5.10 PF Scale

Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/PF Encoder Sensor
Removal procedure
Pay attention to the following instructions.
C A U T I O N
Do not touch the PF Scale with bare hand.
Do not damage the PF Scale.
1.
Peel of the PF Scale that is secured with the double-sided tape (x1) from the
Spur Gear 32.4.
Spur Gear 32.4
Figure 4-72. Removing the PF Scale
DISASSEMBLY/ASSEMBLY
PF Scale
Double-sided tape
Disassembling the Printer Mechanism

4.5.11 PF Motor Assy

Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/PF Encoder Sensor/PF Scale
Removal procedure
1.
Release the PF Motor connector cable from the notches (x2) of the Base
Frame.
Notch
PF Motor Connector Cable
Figure 4-73. Removing the PF Motor Assy (1)
2.
Remove the screws (x3) securing the PF Motor Assy and remove the PF
Motor Assy.
PF Motor Assy
2
Figure 4-74. Removing the PF Motor Assy (2)
Revision A
3
1
Positioning Hole and Dowel
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
Confidential