A123 Slant Adjustment - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF

5.3.4.8 A123 slant adjustment

Print the test pattern and make sure the print quality by referencing the Figure 5-60, "". If
the slant condition is presented, perform the mechanical adjustment.
This test using A1,A2 and A3 nozzle.
Following figure showing menu sequence.
Printing Pattern
Adjust the slant?
Enter
Wait a moment
End with "Pause" key.
Wait a moment
A13 Slant Check End
SelecType
Item
Output Pattern
SelecType
Adjustment
Shift to "A123 Slant Check End"
menu by pressing "Pause" key.
Shift to "B123" or "A123" slant check
menu with following key operation.
"Enter" key: B123 slant check.
"Pause" key: A123 slant check.
Shift to"A123" slant check menu with
"Pause" key.
Print out the pattern with "Enter"
Figure 5-60.
<Print sample>
1.Check items: Black lines, Light Cyan lines and Magenta lines are continue as same level
by a magnifying glass with scale.
2.Printing method.
o
One pass with Uni-D at 360dpi resolution for CR and 45 dpi for PF.
K
Self-Diagnostics
When check the slant, regard the joint
department shown here.
LC
M
K
LC
M
Figure 5-61.