14. Remove two screws fixing the Head ASSY to the Head guide of the right and left.
Disassembly & assembly
Figure 4-96.
15. Remove each two screws fixing the Head guide of the right and left.
Screw
16. Remove compression spring 9.9 that a few of the lower part of head ASSY raises and
be attached between the head base and head ASSY. Do not transforme the spring.
Disassembly Flow
Screw
Head guide
Figure 4-97.
Figure 4-98.
Revision A
Head guide
Spring