4.2.3.10 Removing the PF Encoder

1.
Disconnect the PF Encoder cable connector.
Cable connector
Figure 4-120.
2.
Loosen the set screw (2mm), and remove the bearing stopper.
Figure 4-121.
Disassembly & assembly
3.
Remove four serews fixing the PF base.
4.
Remove the Grid spacer and the Grid end.
Grid spacer
Bearing stopper
Disassembly Flow
PF base
Figure 4-122.
Figure 4-123.
Revision A
Screw
Grid end
166