5.
Fully slide the PF motor backed to the PF Polly side as shown with arrow direction.
Screw
Screw
Figure 4-117.
6.
Remove the two (CP(W) M3x8) screws securing the PF Motor ASSY to the PF motor
bracket, and then remove the PF motor bearing, from the bracket.
Figure 4-118.
Disassembly & assembly
PF Motor bracket
PF timing belt
Screw
When assembling the PF Motor ASSY, move the PF timing belt
manually and check that the PF timing belt revolves around the center
of the reduction pulley. When removing / installing, do not bend or
injure the PF scale.
PF loop scale
If you remove the PF motor, make the necessary adjustments listed in
"PF Timing Belt Tension Adjustment"
Disassembly Flow
Revision A
Steel belt
Timing belt
Figure 4-119.