8.
Remove two screws (CP M3x6 )fixing the Damper holder.
9.
Remove two screws (CP M4x6 )fixing the Damper holder.
Disassembly & assembly
Screw
damper holder
Figure 4-89.
Screw
Figure 4-90.
10. Remove the damper holder with the cable and tube.
When assembly, do not mistake the attachment location of the tube
and pipe.
Do not insert the tube pipe with the damper holder.
11. Remove screw fixing the earth plate. Do not drop the nut of the reverse side.
Nut
Disassembly Flow
Do not mistake the attachment
location of the tube and pipe.
Do not insert the tube pipe
with the damper holder.
Figure 4-91.
Screw
Figure 4-92.