Epson StylusPro 10000 Service Manual page 99

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF
FATAL ERRORS
Fatal error messages appear on the LCD panel to warn users that an unrecoverable error has
occurred. However, in some cases the printer may recover if turned off and back on.
Table 3-29. Fatal Error
Item
LCD message
SERVICE REQ. nnnnnnnn
LED indicator
All LED indicators flash.
status
A fatal error occurs for one of the following reasons.
1) A problem occurred that the user cannot solve by himself.
2) A maintenance part has exceeded its useful life and if not replaced may
Details
cause damage to the printer or printer parts.
3) An illegal function was attempted or illegal command received and the
operation is impossible.
Turn off the printer and turn it back on. If the error does not recur, continue
normal operation.
Recovery
If the same fatal error occurs when you turn the printer back on, see the
following table and perform the necessary service.
Type of Fatal
Refer to the next table.
error
Table 3-30. Fatal Error Code List
Code
00000100
Waste ink pads are full
00000101
CR motor life (Ink tubes also reached their life)
00000102
Nozzle check error compulsory continuity
00000103
RTC backup battery end
00000104
Auto print head optimization system
00000105
Head unit life end
00000106
Cleaning unit life end
Troubleshooting
Description
Description
Troubleshooting Using the Messages
Table 3-30. Fatal Error Code List (continued)
Code
00010000
PF motor/ encoder check error
00010001
PF motor out of step
00010002
PF motor/overcurrent
00010003
PF motor/ in position time-out error
00010004
CR motor/ encoder check error
00010005
CR motor/out of step
00010006
CR motor/overcurrent
00010007
CR motor/ in position time-out error
00010008
Servo interruption watch dog time out error
00010009
System interruption watch dog time out error
0001000A
CR origin sensor mulfanction
0001000B
PF origin sensor mulfanction
0001000C
HS origin sensor mulfanction
0001000D
Cover sensor mulfanction
0001000E
Cover sensor mulfanction
0001000F
CR motor over heat (PWM output malfunction)
00010010
PF motor over heat (PWM output malfunction)
Refer to
00010011
Paper jam error
3.3
00010012
Cap origin error
00010013
Providing system origin error
00010014
Pressurization error
00010015
Liquid sensor overflow (K)
00010016
Liquid sensor overflow(C)
00010017
Liquid sensor overflow (M)
00010018
Liquid sensor overflow (LC)