5.
While holding down the PF encoder from inside, remove two screws and remove the
PF encoder.
Screw
Figure 4-124.
n
When assembly,attach the PF encoder after plug the PF loop
scale to the sensor department of the PF encoder.
n
Do not scars and touching the PF loop scale.
n
When assembly, attach the grid end after two places of bosses are
combined with the hole of the PF base.
n
The grid spacer have to be set to the direction that has a ditch
side.
Disassembly & assembly

4.2.3.11 Removing the Cleaning Unit

If you replace the waste ink absorbers because the service call error
0000100 occurs, you need to replace the specified parts* in the
Cleaning Unit. After replacing them, be sure to initialize the following
counters:
n
Waste ink counter
n
Cleaning unit counter
* Parts to be replaced: Pump Motor, Cap ASSY, Pump ASSY, Cleaner
Head, and Flushing Box ASSY
NOTE: The above mentioned parts are available as a kit:
When you replace the Cleaning Unit, ink may spill from the ink tube
connected to the pump ASSY. Therefore, wipe the ink around the ends
of the ink tubes preliminarily.
1.
Remove the R Side Cover as described in "R Side Cover Removal 124.
2.
Remove the Rear Cover as described in "Rear Cover Removal 126.
3.
Disconnect the cables for the two Motor ASSY from its connector CN12 / CN13 on the
C362DRV board, and take the cables out from the hole in the R side frame.
Disassembly Flow
[Description] MAINTENANCE KIT
[Parts code] 1054038
Figure 4-125.
Revision A
Cable