4.2.1.3 H Top Cover Removal

1.
Open Front cover and Roll paper cover
2.
Remove top side four screws (CS : M4x8), then remove front side two screws (CS :
M4x8).
(Top View)
(Front View)
3.
Remove the H top cover by pulling up and toward the front.
Disassembly & assembly
Top side
four screws
Front two
screws
Screw
Figure 4-12.
Make sure the left and right grounding plates do not get bent during
the disassembly / assembly process.
Disassembly Flow
Revision A
grounding plates
Figure 4-13.