EPSON Stylus Pro 10000/10000CF
3.
Remove front four white screws , then remove the Paper Guide L.
To avoid injury and paper guide L damage, make sure the protection
of drop with proper method.
Disassembly & assembly
Tape
Screw
When installing the Paper Guide L, make sure the five tabs at the top
end slide into the hole of "Sub platen". Then secure with the screws.
Paper Guide L
If just one of the tabs is not inserted properly, roll paper will most
likely still feed normally, but cut sheets might not.
Disassembly Flow
Sub platen
Figure 4-31.
Revision A
129