5.3.4.9 B123 slant adjustment

Print the test pattern and make sure the print quality by referencing the Figure 5-62, "". If
the slant condition is presented, perform the mechanical adjustment.
This test using B1,B2 and B3 nozzle.
Following figure showing menu sequence.
Printing Pattern
Adjust the slant?
Enter
Wait a moment
End with "Pause" key.
Wait a moment
B123 Slant Check End
SelecType
Item
Output Pattern
SelecType
Adjustment
Shift to "B123 Slant Check End"
menu by pressing "Pause" key.
Shift to "Bi-D" adjustment or "B123"
slant check menu with following key
operation.
"Enter" key : Bi-D adjustment.
"Pause" key : B123 slant check.
Shift to"B123" slant check menu with
"Pause" key.
Print out the pattern with "Enter" key.
Figure 5-62.
<Print sample>
1.Check items: Cyan lines, Light Magenta lines and Yellow lines are continue as same level
by a magnifying glass with scale.
2.Printing method.
o
One pass with Uni-D at 360dpi resolution for CR and 45 dpi for PF.
C
Self-Diagnostics
When check the slant, regard the joint
department shown here.
LM
Y
C
LM
Y
Figure 5-63.