Cr Motor - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF

5.3.8.1 CR Motor

Perform the CR motor reliability test.
The carriage runs with the round trip designated number at designated speed.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the CR motor reliability test menu sequence.
Speed CCW : 240CPS
Enter
Speed CCW : 240CPS
Enter
Life Count
Enter
Count : 10
End : 50
o
As for the parameter of CW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
o
As for the parameter of CCW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
o
The maximum value of the reliability number designation is [99,999,999 times].
o
Carriage migration MAX location is 738.06 mm from the starting point location.
o
Carriage migration MIN location is 111.05 mm from the starting point location.
Adjustment
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Figure 5-98.
o
When the [Pause] key is pushed during the reliability test, the test can be broken.
Self-Diagnostics
Revision B
266

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents