3Com V7122 User Manual page 462

Hide thumbs Also See for V7122:
Table of Contents

Advertisement

acBoardTemperatureAlarm Alarm Trap
Table 101
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status: Critical
<text> value: After raise, temperature falls below 55 degrees C (131 degrees F)
Condition:
Corrective Action:
acBoardEvResettingBoard Alarm Trap
Table 102
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status: Critical
<text> value: After raise
Condition:
Corrective Action:
462
acBoardTemperatureAlarm (doesn't apply to the TP-260 board)
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
Critical
equipmentAlarm
temperatureUnacceptable (50)
Board temperature too high
Temperature is above 60 degrees C (140 degrees F)
Cleared
Inspect the system. Determine if all fans in the system are properly operating.
acBoardEvResettingBoard
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
Critical
equipmentAlarm
outOfService (71)
User resetting board
When a soft reset is triggered using the Web interface or SNMP.
Status stays critical until reboot. A clear trap is not sent.
A network administrator has taken action to reset the device. No corrective
action is required.
V7122 GatewayUser Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V7122 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents