Trap
acNATTraversalAlarm
acEnhancedBITStatus
acBoardEthernetLinkAlarm
acPerformanceMonitoringThresholdCrossi
ng
acHTTPDownloadResult
acDChannelStatus
In addition to the listed traps, the device also supports the following standard traps:
dsx1LineStatusChange
dsx3LineStatusChange – implementation pending.
coldStart
authenticationFailure
SNMP Interface Details
This section describes details of the SNMP interface that is required when developing an
Element Manager (EM) for any of the TrunkPack-VoP Series products, or to manage a
device with a MIB browser.
The gateway offers the following SNMP security features:
SNMPv2c community strings
SNMPv3 User-based Security Model (USM) users
SNMP encoded over IPSec (see
Combinations of the above
374
Description
Sent when the NAT is placed in front of a gateway that is
identified as a symmetric NAT. It is cleared when a non-
symmetric NAT or no NAT replaces the symmetric one.
This trap is used to indicate the status of the Built In Test (BIT).
The information in the trap contains board hardware elements
being tested and their status. The information is presented in the
additional info fields.
Sent when an Ethernet link(s) is down.
Sent every time the threshold of a Performance Monitored object
is crossed. The severity field is 'indeterminate' when the crossing
is above the threshold, and 'cleared' when it goes back under the
threshold. The 'source' varbind in the trap indicates the object for
which the threshold is being crossed.
Sent at the success or failure of HTTP download.
Non-alarm trap sent at the establishment, re-establishment, or
release of LAPD link with its peer connection. The trap is sent
with one of the following textual descriptions:
D-channel synchronized
D-channel not-synchronized
IPSec and IKE )
V7122 GatewayUser Guide
Need help?